You are: Home > Resources > Optics > GR-63-CORE Testing
Site Map
 

GR-63-CORE Testing

NEBS
Bellcore Test Description Recommended Test Equipment
5.1.1.1 Low Temperature Exposure and Thermal Shock Ramp down to -40°C at 1/2°C per minute, hold for 72 hours, then move product to ambient  • SE-Series
 • S-3800
 • Walk In
5.1.1.2 High Temperature and Thermal Shock Ramp up to 70°C at 1/2°C per minute, hold for 72 hours, then move product to ambient  • SE-Series
 • S-3800
 • Walk In
5.1.1.3 High Relative Humidity Exposure 40°C and 90% to 95% for 96 hours with controlled temperature to and from 40°C  • SE-Series
 • S-3800
 • Walk In
5.1.2 Operating Temperature and Relative Humidity 14-step profile with temperature extremes from -5°C to 50°C with humidity requirements. Equipment must be operating during this test so high live loads are possible.  • SE-Series
 • S-3800
 • Walk In