GR-63-CORE Testing
| NEBS | |||
| Bellcore Test | Description | Recommended Test Equipment | |
| 5.1.1.1 | Low Temperature Exposure and Thermal Shock | Ramp down to -40°C at 1/2°C per minute, hold for 72 hours, then move product to ambient |
• SE-Series • S-3800 • Walk In |
| 5.1.1.2 | High Temperature and Thermal Shock | Ramp up to 70°C at 1/2°C per minute, hold for 72 hours, then move product to ambient |
• SE-Series • S-3800 • Walk In |
| 5.1.1.3 | High Relative Humidity Exposure | 40°C and 90% to 95% for 96 hours with controlled temperature to and from 40°C |
• SE-Series • S-3800 • Walk In |
| 5.1.2 | Operating Temperature and Relative Humidity | 14-step profile with temperature extremes from -5°C to 50°C with humidity requirements. Equipment must be operating during this test so high live loads are possible. |
• SE-Series • S-3800 • Walk In |
Resources