SM-4-8200 Benchtop Environmental Chamber

Workspace Dimensions—WxDxH: 20 x 20 x 20 inches
50.8 x 50.8 x 50.8 centimeters
Workspace Volume: 4 ft³
113.3 L
Temperature Range: -68ºC to 180ºC
(-90ºF to 356ºF)
Temperature Control Tolerance: =+/- 0.3ºC (+/- 0.5ºF)
Approx. Shipping Weight: 700 lbs
317 kg
Move-In Dimensions—WxDxH: 31 x 42 x 47 inches
78.7 x 106.7 x 119.4 centimeters
Humidity Range: 10% to 95%
Humidity Control Tolerance: =+/- 5%
Electrical Requirements in Full Load Amps 220 / 1 / 50: 22.8
Electrical Requirements in Full Load Amps 230 / 1 / 60: 22.6
Cooling Performance in Minutes 25º to -40ºC: 20
Cooling Performance in Minutes 25º to -54ºC: 40
Compressor Size (2) 3/4 HP
Airflow 250 CFM

Notes

  • Humidity range is limited by a 7°C (45°F) minimum dewpoint and a maximum dry bulb of 85°C (185°F). SM-1.0 Benchtop Environmental Chamber and SM-3.5-3200 Benchtop Environmental Chamber are limited by 15°C (59°F) minimum dewpoint.
  • Humidity control tolerance is measured at a dry bulb temperature above 20°C (68°F).
  • Cooling and heating performance times are an average.
  • S/SM-1.0 Benchtop Environmental Chamber with 115 / 1 / 60 electrical service has a 20 Amp minimum service/20 Amp plug on a 6 ft cord.
  • Temperature Control Tolerance is ±1.1°C (2°F)
  • The addition of accessories may impact performance or increase move-in dimensions.
  • Performance is based upon 60 Hz and 23.9°C (75°F) ambient air. Benchtop Environmental Chambers are designed for normal, non-hazardous laboratory operating conditions. If hazardous materials are involved, please consult your local sales person.
  • Custom options are available.
  • Specifications are subject to change without notice.

My Page