ATSS-80-10-10 Thermal Cycling & Thermal Shock Chamber

Transfer Basket Dimensions—WxDxH: 25 x 14 x 14.5 inches
63 x 35 x 37 centimeters
Temperature Range Hot Zone:: +25°C to +215°C
(+77°F to +419°F)
Temperature Range Cold Zone: -73°C to +180°C
(-100°F to +356°F)
Temperature Control Tolerance: +/-1.1°C (+/-2°F)
Approx. Shipping Weight: 2,160 lbs
980 kg
Maximum Weight Capacity in Basket Pounds / Kg: 100 lbs
45 kg
Move-In Dimensions—WxDxH: 49 x 70 x 83 inches
124 x 178 x 211 centimeters
Compressor Size: (2) 10 Hp Water-cooled
Airflow: 1,200 SCFM (33.9 cubic meters / minute)
Electrical Requirements in Full Load Amps 460 / 3 / 60: 59
Electrical Requirements in Full Load Amps 400 / 3 / 50: 68
Electrical Requirements in Full Load Amps 230 / 3 / 60: 107

Notes

  • Environmental chamber performance is based upon 60 Hz and laboratory ambient conditions of 23.9°C (75°F) with 50% relative humidity, and may vary slightly on 50 Hz power or at other temperature and humidity levels.
  • It is Thermotron’s understanding that the environmental chamber will be used in a non-hazardous environment. The test chamber is not designed for use with or for the purpose of processing hazardous materials. If hazardous materials are involved, please consult the factory for an alternative quote for a properly designed unit.
  • Environmental Chambers are not designed for open petroleum products. Any applications involving open transmission fluids, oils, etc. need to be examined by the applications group for suitable protection.
  • Specifications are subject to change without notice.