DSX-4000 Electrodynamic Shaker – 16″ armature

Force Rating in Sine Peak: 4,000 lbf
17.8 kN
Force Rating in Random RMS: 4,000 lbf 17.8 kN
Shock vs. Load Rating Lbs / Kg: 30g: 375 / 170
50g: 200 / 91
75g: 19 / 8.6
Maximum Velocity—Sine Sweep in ips/mps: 70 / 1.78
Displacement: 3” (76.2mm) pk-pk
(sine, random, shock)
Frequency Range: 0-3,000 Hz
Armature Mass: 66.5 lbs
30.2 kg
Armature Size: 16 inches
40.6 centimeters
Axial Resonance: 2,200 Hz
Mounting Points: 17
Payload Support: 1,000 lbs
454 kg
Stray Magnetic Field (gauss): Less than 8
Approx. Shaker Weight: 6,000 lbs
2,722 kg
Shaker Dimensions—WxDxH: 38 x 53 x 33 inches
97 x 134 x 84 centimeters
Cooling Blower Duct Diameter: 8 inches
20 centimeters
Blower Motor: 5 Hp (3.8 kW)
Blower Dimensions—WxDxH: 25 x 23 x 26 inches
64 x 58 x 66 centimeters
Blower Weight: 145 lbs
66 kg
Airflow: 550 CFM (0.26m3/s)
Amplifier Model: 915/1
Console Dimensions—WxDxH: 34 x 32 x 78.5 inches
86 x 81 x 199 centimeters
Heat Rejected (Maximum): 59,000 BTUH
Electrical Requirements in Full Load Amps 460 / 3 / 60: 40 Amp
Electrical Requirements in Full Load Amps 400 / 3 / 50: 45 Amp

Notes

  • Force Rating Random (RMS) lbf/kN: For a uniform power spectral density, 20-2000Hz, payload mass equal to or greater than twice the armature mass.
  • Maximum Velocity (PK) ips/mps: Rated sine performance is “full field”. Increased velocities may be obtained with reduced field, especially in shock testing.
  • Shock vs. Load Rating Lbs / Kg: Refers to 11 msec, half sine shock pulse.
  • Mounting Points: Aluminum inserts 3/8-16 UNC standard, stainless and other threads available.
  • Stray Magnetic Field: At 6” (150 mm) above mounting surface. Degauss kit optional for reduction to less than 5 gauss at full field. For vertical electrodynamic shaker systems only.
  • Blower Dimensions: Are nominal for a 460/3/60 system. For vertical electrodynamic shaker systems only.
  • Recommended Minimum Service: Is valid for vertical electrodynamic shaker systems only. Horizontal electrodynamic shaker systems will vary based on sliptable requirements. Other voltages are available.
  • Frequency Range: Is dependent on vibration controller resolution, slew rate, and loading.
  • Air Supply: 2SCFM at 90 psi (1 L/sec. at 6.2 BAR).
  • Automatic centering with indicators and optical electronic overtravel protection.
  • This model can have payload capacity increased from 1,000lbs to 1,500lbs as an option.

My Page